NETZSCH - Leading Thermal Analysis.    
   
 
 
 

Vehicle Construction

Vehicle Construction

  • Why does the paint crack off from the substrate?
  • Why does the mold get embrittled and break?
  • Up to what temperature is the car bumper dimensionally stable?
  • Can the curing cycle of the carbon-fiber-reinforced resin be shortened?
  • What material performs adequately under thermal load for air and space travel?
  • Does the thermal conductivity of the turbine materials suffice to ensure adequate cooling?

These or similar questions can be answered with our modern thermoanalytical measuring techniques. We have the ideal solution for your product development, quality assurance, failure analysis and process optimization.

Find out more about the versatile application possibilities of our thermoanalytical measuring systems, the extensive accessory options we offer and our user-friendly software.

Take advantage of all the information contained in your measurements by employing our Advanced Software Packages:


Our product recommendation for you:

DSC 204 F1 Phoenix® DSC 204 F1 Phoenix®
Very high sensitivity and resolution can be realized with this premium DSC, which also features an automatic sample changer (ASC), temperature modulation (TM-DSC), baseline optimization (BeFlat®), correction of thermal resistance and time constants (DSC-correction), even coupling to QMS and FTIR as well as UV-extension for photo-calorimetry.
more information
NEW: Photo-DSC 204 F1 Phoenix® NEW: Photo-DSC 204 F1 Phoenix®
The new Photo-DSC 204 F1 Phoenix® is our answer to the market trend seeking solutions for analyzing the UV curing of light-activated resin systems, adhesives, paints, coatings and dental masses. Further application areas include determining the effect of light on the shelf life of foods or technical oils, fats and lubricants.
more information
TG 209  F1 Iris®TG 209 F1 Iris®
This premium thermobalance, through flexibility in the fittings, covers all imaginable applications of a modern TG in the range up to 1000°C. High sensitivity, short cooling times and the automatic sample changer (ASC), make this TGA particularly well-suited for the compositional analysis of plastics and rubbers.
more information
NEW: DSC 404 F3 Pegasus® NEW: DSC 404 F3 Pegasus®
The new DSC 404 F3 Pegasus® offers a high flexibility for all DSC and DTA applications in quality control and product development. Furnaces and DSC/DTA sensors are available for a broad temperature range (-150...2000°C). Numerous upgrade possibilities allow adaption of this cost-effective system to sophisticated applications.
more information
NEW: STA 449 F3 Jupiter®NEW: STA 449 F3 Jupiter®
The new STA 449 F3 Jupiter® combines the advantages of a high sensitive thermobalance and a true Differential Scanning Calorimeter. Various furnaces and TG, TG-DTA- and TG-DSC-sensors can be used, whereby the system can be easily optimized for the most versatile applications.
more information
DIL 402 CDDIL 402 CD
Expansion measurements at two samples, sample comparisons and differential measurements with a calibration standard are the application fields of the new double and differential dilatometer. A higher sample throughput for routine applications and an easy and fast calibration are the interesting aspects of this new instrument concept.
more information
TMA 402TMA 402
The TMA 402 provides flexibility for the most varied types of burden and extremely precise and high-resolution determination of sample dilation or deformation for practically all materials and fields of application.
more information
DMA 242 CDMA 242 C
The robust construction of the DMA 242 C and the high resolution of the deformation measuring system enable precise measurements on both very rigid and very soft samples. The most varied of deformation types, digital signal filtering, kinetic evaluation and frequency extrapolation make the DMA 242 C to a real all-rounder.
more information
DEA 230 Epsilon SeriesDEA 230 Epsilon Series
There are three different systems in the 230 Epsilon series of Dielectric Cure Monitors: the high-performance, 2-channel DEA 230/2 with the broadest measurement and frequency range, particularly for product development and process optimization, the single-channel DEA 230/1, and the 10-channel DEA 230/10, also suitable for applications in manufacturing.
more information
LFA 457 MicroFlash®LFA 457 MicroFlash®
The LFA 457 MicroFlash® is the most modern product for the determination of thermal diffusivity and conductivity in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing.
more information
QMS 403 C Aëolos®QMS 403 C Aëolos®
The QMS 403 Aëolos® is a very compact mass spectrometer with a heated capillary inlet system, specially designed for routine analysis of volatile decomposition products of thermal analysis.
more information
FTIR CouplingFTIR Coupling
Different thermo-analysis systems can be combined with a Fourier Transform-Infrared Spectrometer (FTIR), which has proved its efficiency especially in the organic field.
more information
 
    print this page back to top back  
 

Thermal Analysis News | Thermal Analysis Products | Thermal Analysis Market Segments | Materials Characterization | Service for Thermal Analysis | Seminars for Thermal Analysis | Applications Measurements | Compliance | Applications Advisory Service | Literature Data Base | Proteus Software | Advanced Software | Contact | NETZSCH worldwide | History | DSC Analysis | TG Analysis | TG-DSC Analysis (STA) | QMS / FTIR Analysis | DIL / TMA / DMA | DEA | LFA / HFM / TCT | RUL / HMOR / PCE / TCT | Sitemap | Imprint