Ceramic / Glass / Building Materials![]() Simultaneous Thermal Analysis (STA) is ideal for investigating issues such as the glass transition of modified glass, binder burnout, dehydration of ceramic materials or decomposition behavior of inorganic building materials, also with gas analysis (QMS). Our product recommendation for you: NEW: STA 449 F3 Jupiter®The new STA 449 F3 Jupiter® combines the advantages of a high sensitive thermobalance and a true Differential Scanning Calorimeter. Various furnaces and TG, TG-DTA- and TG-DSC-sensors can be used, whereby the system can be easily optimized for the most versatile applications. more information NEW: STA 449 F1 Jupiter®With the introduction of the new STA 449 F1 Jupiter® NETZSCH is setting new standards. Unlimited configuration flexibility and unmatched performance are the foundations for a great variety of application possibilities in the fields of ceramics, metals, plastics, and composites over a broad temperature range (-150...2000°C). more information STA 409 CDThe STA 409 CD with single and double lifting devices for various exchangeable furnace types offers the extremely broad temperature range of -160°C to 2000°C. When equipped with a QMS Skimmer Coupling, the STA 409 CD becomes top-notch in the analysis of condensable vapors. more information DIL 402 PCThe dilatometer DIL 402 PC is a universally applicable instrument for routine investigations of ceramic, glass, and metal samples, this dilatometer meets all normal requisites regarding resolution, calibratability, precision and sample atmosphere. This is an easy-to-operate, entry-level instrument for materials characterization for in-plant quality control. more information DIL 402 CDExpansion measurements at two samples, sample comparisons and differential measurements with a calibration standard are the application fields of the new double and differential dilatometer. A higher sample throughput for routine applications and an easy and fast calibration are the interesting aspects of this new instrument concept. more information LFA 427Outstanding attributes of the LFA 427 are high precision and reproducibility, short measuring times, variable sample holders and precisely adjustable atmosphere conditions in the application range from -70°C to 2000°C. The LFA 427 is the most powerful LFA system for use in research & development. more information LFA 457 MicroFlash®The LFA 457 MicroFlash® is the most modern product for the determination of thermal diffusivity and conductivity in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing. more information HFM 436 LambdaWith the HFM 436 Lambda, the thermal conductivity of large-sized, plate-formed insulators is investigated at a fixed or adjustable temperature gradient. The built-in PC – or an externally connected one – delivers the precise measurement data after a short compensation time. more information TCT 426The TCT 426 works according to the hot wire method and is especially designed for the investigation of refractory rock. The measuring cross, parallel wire, and T(R) methods can be used in the instrument. The TCT 426 is indispensable for the efficient use of energy in industrial kiln engineering with refractories. more information QMS 403 C Aëolos®The QMS 403 Aëolos® is a very compact mass spectrometer with a heated capillary inlet system, specially designed for routine analysis of volatile decomposition products of thermal analysis. more information GST 420 PCThe GST 420 PC glaze stress tester complies with the specifications for stress measurements on glazed porcelain recommended by the Deutschen Keramischen Gesellschaft (German Ceramic Society). more information QMS 403/5 SKIMMERHighest detection sensitivity through direct coupling of the STA 409 CD with a quadrupole mass spectrometer (QMS). more information NEW: GHP 456 Titan™The GHP 456 Titan™ allows determination of the thermal conductivity of insulation materials with outstanding reliability and accuracy. Samples 30 cm x 30 cm and up to 10 cm in thickness can analyzed between -160 and 700°C. Innovative plate materials and temperature sensors, special design features and an improved data acquisition and control systems make the system the new benchmark in the field of insulation testing. more information |
||||||||
|
|
|||||||||
Thermal Analysis News | Thermal Analysis Products | Thermal Analysis Market Segments | Materials Characterization | Service for Thermal Analysis | Seminars for Thermal Analysis | Applications Measurements | Compliance | Applications Advisory Service | Literature Data Base | Proteus Software | Advanced Software | Contact | NETZSCH worldwide | History | DSC Analysis | TG Analysis | TG-DSC Analysis (STA) | QMS / FTIR Analysis | DIL / TMA / DMA | DEA | LFA / HFM / TCT | RUL / HMOR / PCE / TCT | Sitemap | Imprint NETZSCH Group | NETZSCH Grinding & Dispersing | NETZSCH Pumps | NETZSCH Oilfield Products |
|||||||||