STA 449 F1 Jupiter® – Simultaneous TGA-DSC

Fascinating Flexibility in Thermal Analysis

STA 449 F1 Jupiter® – Simultaneous TGA-DSC
With the introduction of the new STA 449 F1 Jupiter® NETZSCH is setting new standards. Unlimited configuration flexibility and unmatched performance are the foundations for a great variety of application possibilities in the fields of ceramics, metals, plastics, and composites over a broad temperature range (-150°C ... 2400°C).
NETZSCH_STA-449-F1-Jupiter_Simultaneous_TGA-DSC_Thermogravimetry-and-Differential-Scanning-Calorimetry.jpg
  • Product CategorySimultaneous Thermogravimetry - Differential Scanning CalorimetrySimultaneous Thermogravimetry - Differential Scanning Calorimetry
  • Messmethode STA STA
  • Messparameter Mass changes Mass changes Decomposition temperatures Decomposition temperatures Dehydroxilation Dehydroxilation Corrosion Corrosion Oxidation Oxidation Reduction studies Reduction studies Composition Composition Crystallization enthalpies Crystallization enthalpies Crystallization temperatures Crystallization temperatures Melting enthalpies Melting enthalpies Melting temperatures Melting temperatures Glass transition temperatures Glass transition temperatures Solid-solid transitions Solid-solid transitions Polymorphism Polymorphism Phase diagrams Phase diagrams Purity Determination Purity Determination Liquid crystal transitions Liquid crystal transitions Compatibility Compatibility
  • Norm DIN 51005 DIN 51005 DIN 51006 DIN 51006 ASTM E472 ASTM E472 ISO 7111 ISO 7111 ISO 11358 ISO 11358 ISO/DIN 9924 ISO/DIN 9924 ASTM E1131 ASTM E1131 ASTM D3850 ASTM D3850 ASTM E2040 ASTM E2040 ASTM E2550 ASTM E2550 ASTM E1877 ASTM E1877 ASTM E1582 ASTM E1582
  • Temperature Range von -150 bis 2400
  • Heating Rate von 0.001 bis 1000
  • Cooling Rate von 0.001 bis 50
  • Temperature Accuracy
  • CP Measuring Range von 1 bis 5
  • Gas Atmosphere inert inert oxidizing oxidizing reducing reducing corrosive corrosive vacuum vacuum static static dynamic dynamic
  • Vacuum Tight 10 ^-4 10 ^-4
  • Automatic Sample Changer Yes Yes
  • Evolved gas analysis GC-MS GC-MS FT-IR FT-IR QMS QMS Perseus STA Perseus STA
  • Purpose High Temperature High Temperature

The new STA 449 F1 Jupiter® combines unlimited configuration flexibility and unmatched performance in just one instrument.

  • Thermal stability, decomposition behavior, composition, phase transitions, melting processes to be analyzed comprehensively and quickly
  • Easily to use top-loading system with exceptionally precise balance resolution (25 ng resolution at a weighing range of 5g) and highest long-term stability
  • Interchangeable sensors for DSC measurements with highest sensitivity and best reproducibility for reaction/transition temperatures and enthalpies as well as for measurements of specific heat

    (videoclip for sensor exchange)

  • A variety of optional system enhancements for ideal system adaption to user-defined applications
  • Various furnaces, easily interchangeable by the user, available (optional a swiveling double hoisting device for two furnaces) - please see accessories
  • Pluggable sample carriers (TGA, TGA-DSC, TGA-DTA, etc.)
  • Automatic Sample Changer (ASC) for up to 20 samples
  • Automatic evacuation and refilling (AutoVac)
  • Plenty of accessories, e.g. sample crucibles in the most varied of forms and materials
  • Unique for STA: temperature-modulated DSC (TM-DSC)

Simultaneous Thermal Analysis with IR Capability - NETZSCH STA 449 F1 Jupiter®

By supplementary MS and/or FTIR coupling even more comprehensive analyses are possible.

All these features make the new developed STA 449 F1 Jupiter® the ideal tool for thermal analysis of materials in the fields of research, developments and quality assurance.