The DSC 204F1 Phoenix® is set up for various cooling systems. The entire temperature range from -180°C to 700°C can be covered with the CC 200 F1 (controlled cooling with liquid nitrogen (LN2) and its gas phase (GN2)). Alternatively, an efficient, economical closed-loop intracooler is available, which operates between -85°C and 600°C. Compressed air cooling via compressor or central supply in the laboratory serves for tests above room temperature.
A wide range of crucibles (platinum, stainless steel for pressure applications, etc.) is available for nearly all possible applications and materials.
With the new crucible sealing press with exchangeable inserts, both standard aluminum crucibles and stainless steel crucibles for pressures up to 20 bar can be reproducibly sealed (Photo).
The automatic sample changer DSC 204F1 Phoenix®-ASC is designed for routine measurements. It works day and night, giving you time for other tasks, and provides for optimal use of the DSC 204F1 Phoenix® (e.g. calibrations on the weekend).
A carousel is available for up to 64 sample and reference crucibles which can be automatically run in any order. The controlled generation of the required gas atmosphere in the sample chamber and cooling are automatic.
Of course, each sample can be assigned an individual measurement and evaluation macro. Easy-to-understand input masks lead you through the programming of the measurement series. And it is always possible to insert unplanned analyses into a preprogrammed series of measurements that is already in progress.
For unstable samples or samples with volatile components, an automatic piercing device is available (option), which opens the sealed crucible just prior to the start of the measurement.
The same ASC can also be used with our new TG 209 F1 Iris®.
To analyze the UV curing of light-sensitive resin systems, adhesives, paints, coatings and dental masses, the DSC 204 F1 Phoenix® can be configured as a Photo-DSC. Standard lamps by a variety of manufacturers can serve as a source of radiation.
For adhesives, we recommend the DELOLUX04 high-pressure mercury lamp (315-500 nm), which can easily be triggered using Proteus® software.
For paints and inks, we recommend the DSC be equipped with an OmniCure® S2000 lamp. The measurement parameters (e.g. exposure time and intensity) can be programmed and monitored by segment via the Proteus® software.
The luminous intensity of the high-pressure mercury lamp can be calibrated with the Radiometer R2000.