The QMS 403 Aëolos® quadrupole mass spectrometer is a new compact mass spectrometer with a heated capillary inlet system for routine analysis of gases and, in particular, volatile decomposition products of thermal analysis. This system has been optimized for coupling to differential scanning calorimeters, dilatometers and thermogravimetric analyzers by:

  • Increasing the temperature of the entire gas transfer system to 300°C
  • An improved single-stage inlet system with a low-reaction fused silica capillary and ultrasonic expansion in the ion source
  • Integration of the mass spectrometer software and data exchange for user-friendly operation from the Proteus® thermal analysis software.

The high temperature of the gas transfer system and the absence of pressure reduction orifices practically eliminate condensation of decomposition products during thermal analysis experiments. This achieves a high detection sensitivity and facilitates quantitative detection of all identified gas components.
Via the inlet system with the fused silica capillary, other gas sources can be investigated with the QMS 403 C Aëolos® independent of thermal analysis; for that purpose, the QMS is operated with the self-contained software.

The concept of the NETZSCH thermal analysis instruments has been laid out from the start for coupling with gas analysis systems like the QMS 403 C Aëolos® or an FTIR system with a gas cell, through consistent optimization of the gas paths with complete heating from the furnace to the gas detector. This eliminates gas loss through condensation at cold spots and only very low carrier gas flows are sufficient for complete transfer. The minimal dilution of the volatile sample products released results in high detection sensitivity with the QMS 403 C Aëolos®.

 

GeneraleTecnicaSoftwareApplicazioniAccessoriLetteratura 

Per favore, visitate anche le seguenti pagine prodotti:

DSC 204 F1 Phoenix®

DSC 204 F1 Phoenix®


DSC 404 C Pegasus®

DSC 404 C Pegasus®


TG 209  F1 Iris®

TG 209 F1 Iris®


STA 409 PC Luxx®

STA 409 PC Luxx®


STA 449 C Jupiter®

STA 449 C Jupiter®


DIL 402 C

DIL 402 C


 
    stampa la pagina torna su indietro  
 

Notizie | Prodotti | Rami / Industrie | Caratteristici dei materiali | Assistenza Tecnica | Seminari | Analisi e Applicazioni | Conformità | Servizio Applicazioni Suggerimenti | Letteratura | Software Proteus® | Advanced Software | Contatti | Locazioni | NETZSCH-storia | DSC/DTA | TG/TGA | STA (TG-DSC) | QMS / FTIR | DIL / TMA / DMA | DEA | LFA/HFM/TCT | RUL/HMOR/PCE/TCT | Sitemap | Editoriale

Gruppo NETZSCH | NETZSCH Macinazione e Dispersione | NETZSCH Pompe | NETZSCH Oilfield Products