![]() |
![]() |
||||||||||||||||||||
|
|||||||||||||||||||||
|
|
Dynamic mechanical multi-talent for visco-elastic propertiesDMA 242 C – Analisador Dinâmico Mecânico
DMA 242 C - Technical Specifications (subject to change)Informação & Serviço:Informação de Produto Informação de Serviço
![]() Schematic of DMA 242 C ![]() Three-point Bending The sample is supported on two edges, while the cutting end of the push rod applies a load to the sample from above. The spacing between the two edges is in accordance with DIN 53457. Four different bending lengths between 10 and 50 mm are available. This deformation mode is ideal for materials with a high storage modulus such as filled or reinforced thermoplastics and thermosets (composites) or metals and alloys. ![]() Dual Cantilever Bending The ends of the sample are tightly clamped. This arrangement is especially suitable for samples of mid modulus range (rubber and thermoplastics). Holders for three different bending lengths between 2 and 32 mm are availabe. By leaving one end of the sample free, measurements can be made in the single cantilever bending mode as well. ![]() Compression The sample (rubber, foams, biopolymers, pasty materials, etc.) is placed on a flat surface in the sample holder and pressure is applied from above with the plate-shaped end of the push rod. Different diameters up to 30 mm are availabe. By using a ceramic disk and a push rod of fused silica, a small temperature gradient can be achieved (especially for foams and rubber). If the end of the push rod is pointed rather than flat, the term is penetration. For example, this type of stressing is suitable for the investigation of coatings. ![]() Linear Shearing Two identical samples are pressured or glued in sandwich geometry between the flat surfaces of the sample holder and the push rod. The load is applied via the platelike extension of the push rod. Two types of sample holders are especially suited for soft materials such as rubber and adhesives. ![]() Tension The tension mode is preferable for the measurement of films and fibers or thin rubber samples. The lower end of the sample is held in place, wheras the upper end is clamped to the oscillating push rod.
Por favor, também visite as seguinte páginas de produtos:
|
||||||||||||||||||||
|
|
|||||||||||||||||||||
Análise Térmica - Novidades | Análise Térmica - Produtos/ Soluções | Análise Térmica - Segmentos de Mercado / Indústrias | Análise Térmica - Materiais/Aplicações | Análise Térmica - Serviço | Análise Térmica - Seminários | Aplicações de Medição | Conformidade | Serviço Consultivo de Aplicações | Media Center | Proteus® Software | Software Avançado | Contacto | NETZSCH do Brasil | Calorimetria Exploratória Diferencial / Análise Térmica Diferencial (DSC/DTA) | Calorimetria de Múltiplos Módulos (MMC) | Termogravimetria (TGA) | Termogravimetria Simultânea - Calorimetria Exploratória Diferencial (TGA-DSC) | Análises de Gás / Acoplamentos (QMS, FTIR, TG-GC-MS, SKIMMER) | Dilatometria (DIL) | Análises Termomecânicas (TMA) | Análise Térmica Dinâmico-Mecânica (DMTA) | Calorimetria Adiabática de Reação | Análises Dielétricas (DEA) | usividade e Condutibilidade Térmica (LFA / GHP / HFM / TCT) | Testes de Refratários (RUL/CIC, HMOR, PCE, TCT) | Sitemap | Imprint |
|||||||||||||||||||||