
Products / Solutions
Make your choice from among our diverse variety of instruments for Thermal Analysis. NETZSCH Analyzing & Testing has consistently invested its long-time experience into innovative new developments and advanced technologies conceived for state-of-the-art application tasks in materials research and development, quality assurance and process optimization.
Our products and services embody technological leadership, expertise, and reliable quality for the user’s benefit.
Get to know more about the NETZSCH products in our corresponding overview brochure and product outline.
Differential Scanning Calorimetry (DSC) / Differential Thermal Analysis (DTA)
DSC (Differential Scanning Calorimeters) and DTA (Differential Thermal Analyzer) quantitatively determine conversion temperatures and enthalpies for solids and liquids by measuring the heat flows to both the sample and to a reference as a function of temperature and time.
more information
Thermogravimetric Analysis / Thermogravimetry (TGA, TG)
Thermogravimetric Analysis/Thermogravimetry (TGA, TG) determines the temperature- and time-dependent changes in the mass of a sample that occur during a specific temperature program and in a defined atmosphere. The respective instrument is called a thermobalance.
more information
Simultaneous Thermogravimetry - Differential Scanning Calorimetry STA
(TG-DSC)
STA denotes the concurrent application of two or more measuring methods to the same sample. The classic simultaneous method is the combination of thermogravimetry with DSC or DTA.
more information
Dilatometry (DIL / GST)
For precise measurements of dimensional changes on solids, dilatometry (DIL) is the method of choice.
more information
Thermomechanical Analysis (TMA)
For highly precise measurement of dimension changes to solids, melts, powders and pastes at a programmed temperature change and with negligible sample strain, Thermo-Mechanical Analysis (TMA) is the method of choice. The measurement of the dimensional changes can additionally be carried out with adjustable sample strain.
more information
Dynamic-Mechanical Analysis / Dynamic Mechanical Thermal Analysis
(DMA / DMTA)
Dynamic-Mechanical Analysis (DMA) / Dynamic Mechanical Thermal Analysis (DMTA) measures visco-elastic properties by applying an oscillating force to the sample.
more information
Multiple Mode Calorimetry (MMC)
Like a DSC, the Multi Modul Calorimeter (MMC) measures chemical reactions, phase changes, and specific heat but on gram-size samples. The NETZSCH development team has created a totally new calorimeter system which can be used in commercial R&D, universities and research centers and QC/QA of various industries.
Accelerating Rate Calorimetry
Accelerating Rate Calorimeters that help industry operate safely and profitably. As highly versatile, miniature chemical reactors, they measure thermal and pressure properties of exothermic chemical reactions. The resulting information helps engineers and scientists identify potential hazards and address key elements of process safety design including emergency relief systems, effluent handling, process optimization, and thermal stability.
more information
Dielectric Analysis (DEA)
Dielectric Analysis (DEA) measures changes in dipole orientation and ion mobility in polymers and cross-linked systems by stimulation with an alternating voltage via sensor electrodes. The DEA method can also be used for online-processes (e.g. cure monitoring) with a suitable sensor technique.
more information
Thermal Diffusivity / Thermal Conductivity (LFA / GHP / HFM / TCT)
The Laser Flash Method (LFA) is a well established technique for the determination of thermal diffusivity, in which the increase in the sample’s temperature resulting from the absorption from a laser flash is measured. With HFM (Heat Flow Meter), GHP and TCT (Thermal Conductivity Tester), the thermal conductivity of insulating materials and refractories can be determined.
more information
Refractory Testing (RUL/CIC, HMOR, PCE, TCT)
Refractoriness under load (RUL) and creep in compression (CIC) describe the deformation resistance of a sample body under loading as a function of temperature and time. The bending strength (HMOR - Hot Modulus of Rupture) is determined with a hot bending strength tester. The melting behavior is described by the pyrometric cone equivalent (PCE).
more information
Evolved Gas Analysis (EGA) - QMS, FTIR, GC-MS, SKIMMER
Mass- and Infrared spectrometry (methods for EGA: Evolved Gas Analysis) serve to detect and identify volatile emissions from a sample during a temperature treatment. We offer perfect solutions for coupling of QMS, GC-MS and FTIR with our thermal analyzers.
more information
Software
The Proteus® software package integrates all functionalities for carrying out measurements on any NETZSCH instrument with comprehensive routines for the evaluation of measuring data and import of external data.
Additionally, we deliver unique Advanced Software solutions, such as Thermokinetics.
more information












