Photo-DSC 204 F1 Phoenix® for UV curing and more

Photo-DSC 204 F1 Phoenix® - Differential Photocalorimeter

 
GeneralTechniqueSoftwareApplicationsAccessoriesLiterature 

Alternative content

Get Adobe Flash player

Info & Service:

Product Information
Would you like to request more information on a particular product?
We will be happy to send you what you need.
Continue

Service Information
Find out more about our various service offerings.
We are at your assistance!
Continue

The main advantage of light-curing systems is their fast reaction time. Monomer solutions which are mostly free of solvents can be cured within only a few seconds and already at low temperatures. A combination of thermal and light curing reactions is often applied to dual cure adhesives or paints.

software has been released.


The NETZSCH Photo-DSC 204 F1 Phoenix®, Differential Photocalorimeter, works in the temperature range from -100°C to 200°C. The Differential Photocalorimetry instrument has a gas-tight measuring cell and the purge gas control is regulated by a mass flow controller (MFC).

For our Differential Photocalorimeter, Photo-DSC 204 F1 Phoenix®, most standard industry or laboratory lamps for cationic or radically curing material systems can be used.

For adhesives, we recommend the DELOLUX04 high-pressure mercury lamp (315-500 nm), which can easily be triggered using the Proteus® software.
For paints and inks, we recommend the DSC (Differential Photocalorimeter) be equipped with an OmniCure® S2000 lamp. The measurement parameters (e.g. exposure time and intensity) can be programmed and monitored by segment via the Proteus® software.
The luminous intensity of the high-pressure mercury lamp can be calibrated with the Radiometer R2000.

The modified automatic lid-lifting device of the Differential Photocalorimeter, DSC 204 F1 Phoenix®, guarantees a defined distance between the two light conductors and the sample and reference.
This achieves high reproducibility of measurement results.
For your normal DSC analyses (DSC = Differential Scanning Calorimetry) above 200°C, a retrofit of the standard lid-lifting device is possible, or the manual lid can also be used without problems.

For high sample throughput or for repeat measurements, use of our Automatic Sample Changer (ASC) for up to 64 samples is recommended.

 

GeneralTechniqueSoftwareApplicationsAccessoriesLiterature 

Please also visit the following product pages:

 DSC 200 F3 Maia®

DSC 200 F3 Maia®


DSC 204 F1 Phoenix®

DSC 204 F1 Phoenix®


DSC 204 HP Phoenix®  - High-pressure Differntial Scanning Calorimeter

DSC 204 HP Phoenix® - High-pressure Differntial Scanning Calorimeter


DMA 242 C

DMA 242 C


 
    print this page back to top back  
 

Thermal Analysis News | Thermal Analysis Products | Thermal Analysis Market Segments | Materials Characterization | Service for Thermal Analysis | Seminars for Thermal Analysis | Applications Measurements | Compliance | Applications Advisory Service | Media Service | Proteus Software | Advanced Software | Contact | NETZSCH worldwide | History | DSC Analysis | Multiple Mode Calorimetry (MMC) | TGA Analysis | TGA-DSC Analysis (STA) | QMS / FTIR, TG-GC-MS Analysis | DIL | TMA | DMA / DMTA | Adiabatic Reaction Calorimetry | DEA | LFA / GHP / HFM / TCT | RUL / HMOR / PCE / TCT | Sitemap | Imprint

NETZSCH Group | NETZSCH Grinding & Dispersing | NETZSCH Pumps