Characterization of Porcelain Raw Material
This STA measurement on porcelain raw material shows three mass-loss steps. Below approx. 250°C, the evaporation of humidity occurred. At temperatures between 250°C and 450°C, the burn-up of organic content was observed, during which 156 J/g of energy was released. The dehydration of kaolin occurred above 450°C and required 262 J/g. The mass spectrometer signals for mass numbers 18 and 44 reflect the corresponding release of H2O and CO2. The exothermic DSC peak at 1006°C with an enthalpy of -56 J/g is due to an solid-solid transition.

Building Material: Glass Wool
Glass Wool is often used for the insulation of houses and heating pipes. The STA measurement shows three mass-loss steps below approx. 600°C, which are due to the evaporation of humidity and the burn-up of organic binder. The latter can be seen from the strongly exothermic DSC signal in this temperature range. The step in the DSC signal at 728°C with an increase in the specific heat of 0.41 J/(g*K) is due to the glass transition. The exothermic DSC peak at 950°C with an enthalpy of -287 J/g is due to crystallization; the endothermic effects between approx. 1050°C and 1250°C with an entire enthalpy of 549 J/g show the melting. The slight mass changes above 700°C are most probably due to oxidation and evaporation of impurities.

 

GeneralTechniqueSoftwareApplicationsAccessoriesLiterature 

Please also visit the following product pages:

DSC 404 F3 Pegasus®

DSC 404 F3 Pegasus®


STA 449 F1 Jupiter®

STA 449 F1 Jupiter®


DIL 402 PC

DIL 402 PC


QMS 403 C Aëolos®

QMS 403 C Aëolos®


FTIR Coupling

FTIR Coupling


 
    print this page back to top back  
 

Thermal Analysis News | Thermal Analysis Products | Thermal Analysis Market Segments | Materials Characterization | Service for Thermal Analysis | Seminars for Thermal Analysis | Applications Measurements | Compliance | Applications Advisory Service | Media Service | Proteus Software | Advanced Software | Contact | NETZSCH worldwide | History | DSC Analysis | Multiple Mode Calorimetry (MMC) | TGA Analysis | TGA-DSC Analysis (STA) | QMS / FTIR, TG-GC-MS Analysis | DIL | TMA | DMA / DMTA | Adiabatic Reaction Calorimetry | DEA | LFA / GHP / HFM / TCT | RUL / HMOR / PCE / TCT | Sitemap | Imprint

NETZSCH Group | NETZSCH Grinding & Dispersing | NETZSCH Pumps