LFA 467 HT HyperFlash® – Light Flash Apparatus

LFA 467 HT HyperFlash® – Light Flash Apparatus

Novas Dimensões na Medição de Difusividade Térmica e Condutividade – Rápida, Simples, Econômica.

Accurate thermal diffusivity and thermal conductivity measurements between RT and 1250°C with Xenon Flash
The LFA 467 HT HyperFlash® is based on the already-established LFA 467 HyperFlash® technology and requires no laser class due to the innovative light source system. The long lifetime of the xenon lamp provides cost-effective measurements until 1250°C without costly consumables.

ZoomOptics – For precise measurement results by an optimized field of view
The patented ZoomOptics system (patent no.: DE 10 2012 106 955 B4  2014.04.03) optimizes the field of view of the detector, thus eliminating any influences caused by aperture stops. The result is a significant increase in the precision of the measurement results.

Ultra-fast sampling rate (up to 2 MHz) and extremely short pulse widths (up to 20 µs) enabling measurement of thin and highly conducting materials
The data acquisition rate of the LFA 467 HyperFlash® series was increased to 2 MHz. This acquisition rate applies to both the IR detector and the pulse mapping channels. Thereby, highly conductive and/or thin materials requiring very short test times can be reliably tested.
When testing metal (0.3 mm) and polymer foils (30 μm), an optimum sampling rate and pulse width can be selected. The patented pulse mapping system accounts for the finite pulse width effect and heat losses (patent no.: US7038209 B2; US20040079886; DE1024241).

 

Vacuum-tight for defined atmospheres and prevention of oxidation
An internal pump device supports defined atmospheres by an automatic evacuation function prior to each measurement. Additional connections for external pump devices are available. The vacuum tight platinum furnace allows for heating rates up to 50 K/min.

High throughput and precision – 4 samples 4 thermocouples
Effective sample throughput over the entire temperature range is guaranteed by the automatic sample changer (ASC). Each of the ASC’s four sample positions is equipped with its own thermocouple. This results in drastically minimized temperature deviations between the sample and temperature measuring position. The ASC is designed for sample dimensions of 12.7 mm (round) and 10 mm (round and square).

All accomplished while still possessing the smallest footprint
The LFA 467 HT HyperFlash® is the first flash lamp-based LFA system to reach temperatures until 1250°C. One single furnace with an integrated sample changer covers the entire temperature range, providing the small footprint that the LFA 467 HyperFlash® series is well known for. Even at such elevated temperatures, an efficient internal water cooling circuit keeps the temperature of the surrounding components within a safe range, thereby reducing the liquid nitrogen consumption of the IR detector.

       

Dados Técnicos

Dados Técnicos

(sujeito a alterações)

  • Temperature range:
    RT to >1250°C
  • Heating rate (max.):
    50 K/min
  • IR detectors:
    • InSb: RT > 1250°C
    • Detector refill device
  • Data acquisition rate:
    up to 2 MHz (for both temperature detection and pulse mapping)
  • Thermal Diffusivity:
    0.01 mm2/s to 2000 mm2/s
  • Thermal Conductivity:
    < 0.1 W/(m*K) to 4000 W/(m*K)
  • Patented pulse mapping technique
    for finite pulse correction and improved cp determination
  • Atmospheres:
    Inert, oxidizing, static and dynamic
  • Vacuum:
    10-4 mbar
  • Sample holders:
    for round and square samples
  • Gas control:
    MFC and AutoVac
Schematic of the LFA 467 HT HyperFlash; the light beam heats the lower sample surface and an IR detector measures the temperature increase on the upper sample surfaceSchematic of the LFA 467 HT HyperFlash®;
the light beam heats the lower sample surface and an IR detector measures the temperature increase on the upper sample surface
ZoomOptics

ZoomOptics

ZoomOptics para maior precisão dos resultados de medição sem medição de erros

Geralmente, a área da superfície superior a ser varrida pelo detector é customizada para caber o tamanho máximo de amostra de até 25.4 mm. Amostras com um diâmetro menor são, mais frequentemente, cobertas com uma máscara ou uma capa para ocultar zonas periféricas para extensão maior possível. Uma vez que todos os corpos, contudo, emitem radiação infravermelha – ou seja, até mesmo com o uso da máscara ou da capa no material – o sinal resultante do detector é inevitavelmente influenciado. A extensão na qual esta influência é visível depende da diferença de difusividade térmica entre a amostra e a máscara/capa do material. O resultado – no segmento final do aumento principal da temperatura – pode ser tanto um aumento contínuo ou um nivelamento prematuro do sinal do detector. Em qualquer caso, uma mudança da metade do tempo ocorre, falsificando assim a difusividade térmica calculada. 

O ZoomOptics permite que o campo de visão do detector a ser ajustado até que o único aumento de temperatura registrado seja da amostra e não seja influenciado pelo ambiente ou máscaras que possam ter algum efeito. O valor pré-estabelecido – que cobre a maioria das aplicações – é de 70%; Entretanto, este valor pode ser ajustado individualmente pelo operador de acordo com a geometria da amostra dada.

A vantagem do ZoomOptics é ilustrada claramente pelo exemplo de medida na Pirocerâmica seguinte:

Thermal diffusivity resultsThermal diffusivity results
Mídia Digital

Mídia Digital

Catálogo

Catálogo

Transmissão pela internet

NETZSCH Webinar Introductory-Level Laser Flash Analysis
NETZSCH-WebinarCommonly Used Method for Thermal Conductivity Determination
NETZSCH-Webinar Thermal Analysis Goes Green Applications in the Field of Renewable Energies
NETZSCH CEN Webinar - Thermophysical Properties and Characterisation of Polymers using the Flash Technique

Você também pode estar interessado em:

LFA 467 HyperFlash® – Light Flash Apparatus

O novo LFA 467 HyperFlash®  apresenta uma ampla faixa de temperatura, altíssima eficiência (com trocador de amostras para 16 amostras), taxas de aquisição de dados extremamente rápido e um sistema de lentes inteligentes (ZoomOptics) entre a amostra e o detector.

HFM 436 Lambda - Medidor de Fluxo de Calor

Com o Medidor de Fluxo de Calor, HFM 436 Lambda, a condutividade térmica dos isoladores de grande porte, em formato de placas, é investigada à um gradiente de temperatura fixo ou ajustável. O PC embutido - ou um PC ligado externamente - fornece os dados precisos de medição, após um curto tempo de compensação.

GHP 456 Titan®

Inovação: Guarded Hot Plate System GHP 456 Titan® para Determinação da Condutividade Térmica de Isolamentos